Author Topic: Electrical anomaly please explain ...  (Read 7118 times)

DeepCut

  • Hero Member
  • *****
  • Posts: 640
Electrical anomaly please explain ...
« on: April 01, 2010, 01:52:33 PM »
Hi. Need help, don't understand why this is happening.

http://www.youtube.com/watch?v=UuBaoY3fw5o

I have DC power supply powering a bifilar coil at 6V.

Power winding on the coil is drawing, on average, 0.1A.

Tiny rotor with 4 magnets.

Reed switch.

The multimeter is reading up to 100's of volts and tens of amps being output on the secondary winding of the coil.

The strange thing is is that whichever setting i choose to read from on the multimeter the reading is always within that range, ie, if i'm on millivolts then i get, say, 40 mV or if i am on the 200V setting i get 40V ...

Multimeter and PSU are brand new, i have tested them both and they operate normally.

Obviously this is erroneous but why is it happening ?

FatBird

  • Hero Member
  • *****
  • Posts: 1178
Re: Electrical anomaly please explain ...
« Reply #1 on: April 01, 2010, 02:35:37 PM »
I have seen this also.

The reason is because inexpensive Chinese digital meters don't have very good shielding to RF.  The more RF a circuit outputs, the more erroneous the readings get.

If you use an "old fashioned" analog meter with a needle, you will get more accurate readings.

.

DeepCut

  • Hero Member
  • *****
  • Posts: 640
Re: Electrical anomaly please explain ...
« Reply #2 on: April 01, 2010, 02:46:26 PM »
Thanks for that i'll order one.

gyulasun

  • Hero Member
  • *****
  • Posts: 4117
Re: Electrical anomaly please explain ...
« Reply #3 on: April 01, 2010, 02:53:35 PM »
Hi Folks,

There is another possibility, besides what FatBird wrote.

Try to connect an electrolytic capacitor in parallel with the diode bridge output. (even a 47uF or higher (microFarad) 35 - 63V rated would do)

I suspect all the voltage spikes from the coil go into the meter via the bridge and fool the meter inner circuits.  A simple try would be worth it.

EDIT: nevertheless, an analog multimeter is always good to have, besides a DMM, to learn about more truth when tinkering.

Gyula

ramset

  • Hero Member
  • *****
  • Posts: 8073
Re: Electrical anomaly please explain ...
« Reply #4 on: April 01, 2010, 03:11:17 PM »
Deepcut
Great to see another dedicated researcher,I'm glad the fellows that "know"
could offer some assistance.
I hope to see more "anomaly's" from you soon [of the third kind] :o;

Thanks
Chet

DeepCut

  • Hero Member
  • *****
  • Posts: 640
Re: Electrical anomaly please explain ...
« Reply #5 on: April 01, 2010, 03:31:43 PM »
Thanks for replies and help :)

I am picking up an old CRT monitor from a hazardous waste place this afternoon and will grab a cap from it.

Will have analogue meter delivered Tuesday.