Language: 
To browser these website, it's necessary to store cookies on your computer.
The cookies contain no personal information, they are required for program control.
  the storage of cookies while browsing this website, on Login and Register.

GDPR and DSGVO law

Storing Cookies (See : http://ec.europa.eu/ipg/basics/legal/cookies/index_en.htm ) help us to bring you our services at overunity.com . If you use this website and our services you declare yourself okay with using cookies .More Infos here:
https://overunity.com/5553/privacy-policy/
If you do not agree with storing cookies, please LEAVE this website now. From the 25th of May 2018, every existing user has to accept the GDPR agreement at first login. If a user is unwilling to accept the GDPR, he should email us and request to erase his account. Many thanks for your understanding.
Amazon Warehouse Deals ! Now even more Deep Discounts ! Check out these great prices on slightly used or just opened once only items.I always buy my gadgets via these great Warehouse deals ! Highly recommended ! Many thanks for supporting OverUnity.com this way.

User Menu

Tesla Paper

Free Energy Book

Get paid

Donations

Please Donate for the Forum.
Many thanks.
Regards, Stefan.(Admin)

A-Ads

Powerbox

Smartbox

3D Solar

3D Solar Panels

DC2DC converter

Micro JouleThief

FireMatch

FireMatch

CCKnife

CCKnife

CCTool

CCTool

Magpi Magazine

Magpi Magazine Free Rasberry Pi Magazine

Battery Recondition

Battery Recondition

Arduino

Ultracaps

YT Subscribe

Gravity Machines

Tesla-Ebook

Magnet Secrets

Lindemann Video

Navigation

Products

Products

WaterMotor kit

Statistics


  • *Total Posts: 524093
  • *Total Topics: 15602
  • *Online Today: 44
  • *Most Online: 103
(December 19, 2006, 11:27:19 PM)
  • *Users: 1
  • *Guests: 10
  • *Total: 11

Author Topic: How to get right values from an non-50Hz signal using a DMM?  (Read 5122 times)

gast

  • Guest
How to get right values from an non-50Hz signal using a DMM?
« on: August 26, 2005, 11:06:59 AM »
Hi all,

does anybody have an idea how to measure comparable values (voltage/ampers) of an sqarepulse-signal using only a digital multimeter?
I dont want to get absolute values (V/A), but I want to get linear values independent from the signals frequency.   

I guess a multimeter which is build for 50 Hz measurement shows always wrong values on signals other than 50 Hz.
But I guess also that the "error-factor" changes with the frequency (= not linear).   

My idea is to rectify the signal with 4 lowdrop-diodes and a big capacitor to get an DC-voltage.
Ampere measurements I would do by a voltage measurement over a small load (10 ohm or so).   

Any better ideas (except "buy an oszilloscope ;-) )?

Gast
« Last Edit: August 26, 2005, 11:41:54 AM by Gast »

Free Energy | searching for free energy and discussing free energy


Offline Warpspeed

  • Newbie
  • *
  • Posts: 3
Re: How to get right values from an non-50Hz signal using a DMM?
« Reply #1 on: September 17, 2005, 11:39:12 AM »
One low cost but fairly accurate way to measure true ac power (watts) not reactive power (v/a) is to illuminate a suitably sized light bulb in a light proof box with your high frequency signal.

What you then do is measure the relative light output somehow. It doesn't need to be anything fancy, a photocell or light dependant resistor connected to your multimeter. So you get some sort of relative light reading.

You then connect the identical light bulb up to a variable voltage dc power supply, and adjust the brightness to an identical setting.  By accurately measuring dc volts, and dc milliamps you can then work out the dc power required to get the same exact light level.

This will work up to extremely high frequencies, and with funny non symmetrical waveforms too. The more careful you are, the more accurate it will be.

Even with an oscilloscope, measuring ac power is extremely difficult because the voltage and current waveforms can be well out of phase.

Offline hartiberlin

  • Administrator
  • Hero Member
  • *****
  • Posts: 7972
    • free energy research OverUnity.com
Re: How to get right values from an non-50Hz signal using a DMM?
« Reply #2 on: September 17, 2005, 05:15:21 PM »
Yes, Warpspeed , this is right ! Many thanks for bringing up the comparising method
via light bulbs.As the human eye is also very sensitive you can place 2 bulbs this way
side by side and compare the DC powered bulb to the AC powered bulb and thus
compare the wattage output relative easily.

Thanks for bringing this very usefull and cheap measurement method up.

Regards, Stefan.

Free Energy | searching for free energy and discussing free energy

Re: How to get right values from an non-50Hz signal using a DMM?
« Reply #2 on: September 17, 2005, 05:15:21 PM »
Sponsored links:




Offline bolt

  • Hero Member
  • *****
  • Posts: 926
Re: How to get right values from an non-50Hz signal using a DMM?
« Reply #3 on: October 16, 2008, 04:58:23 AM »
And dont use compact power savers either they can light up from 1 watt to 50 watts and still not change much on brightness. Another way is find a value resistor on the input that just gets hot then take that out and put the same value in the output. If the output one goes up in smoke you have OU :)

 