Author Topic: Transformer Related Question ??  (Read 4761 times)

magnetman12003

  • Hero Member
  • *****
  • Posts: 854
Transformer Related Question ??
« on: August 08, 2015, 09:30:12 PM »
I have a hi frequency  transformer with a secondary of 2200 ohms and a primary of 25 ohms.

Notice the 88 to 1 ratio.     I have a power supply that puts out 1232 volts AC and wish to see 14 volts AC output.  Notice the 88 to 1 ratio again.

Question:  Can I connect the  transformers secondary to the power supplies 1232 volts and see 14 volts AC out of the primary?

The question is a learning curve for me.

MarkE

  • Hero Member
  • *****
  • Posts: 6830
Re: Transformer Related Question ??
« Reply #1 on: August 09, 2015, 12:41:53 AM »
I have a hi frequency  transformer with a secondary of 2200 ohms and a primary of 25 ohms.

Notice the 88 to 1 ratio.     I have a power supply that puts out 1232 volts AC and wish to see 14 volts AC output.  Notice the 88 to 1 ratio again.

Question:  Can I connect the  transformers secondary to the power supplies 1232 volts and see 14 volts AC out of the primary?

The question is a learning curve for me.
Transformer impedance changes as the square of the turns ratio.  Voltage changes proportionally to the turns ratio.   88:1 impedance is about 9.4:1 turns ratio.

forest

  • Hero Member
  • *****
  • Posts: 4076
Re: Transformer Related Question ??
« Reply #2 on: August 09, 2015, 10:11:52 AM »
MarkE


Would that mean 1:1 transformer is always 1:1 ?

MarkE

  • Hero Member
  • *****
  • Posts: 6830
Re: Transformer Related Question ??
« Reply #3 on: August 09, 2015, 10:32:09 AM »
MarkE


Would that mean 1:1 transformer is always 1:1 ?
Ignoring losses, yes.

pomodoro

  • Hero Member
  • *****
  • Posts: 720
Re: Transformer Related Question ??
« Reply #4 on: August 09, 2015, 12:52:46 PM »
Those values are actually the transformer specs, not what you measured with a multimeter, correct? If so, then all is good. Also, if its a HF transformer, make sure you use it only at HF.

MarkE

  • Hero Member
  • *****
  • Posts: 6830
Re: Transformer Related Question ??
« Reply #5 on: August 09, 2015, 01:38:21 PM »
Those values are actually the transformer specs, not what you measured with a multimeter, correct? If so, then all is good. Also, if its a HF transformer, make sure you use it only at HF.
Do you have a problem with molten enamel?