Storing Cookies (See : http://ec.europa.eu/ipg/basics/legal/cookies/index_en.htm ) help us to bring you our services at overunity.com . If you use this website and our services you declare yourself okay with using cookies .More Infos here:
https://overunity.com/5553/privacy-policy/
If you do not agree with storing cookies, please LEAVE this website now. From the 25th of May 2018, every existing user has to accept the GDPR agreement at first login. If a user is unwilling to accept the GDPR, he should email us and request to erase his account. Many thanks for your understanding

User Menu

Custom Search

Author Topic: Mosfet peak current on duty measurements  (Read 7240 times)

Jeg

  • Hero Member
  • *****
  • Posts: 1532
Mosfet peak current on duty measurements
« on: November 21, 2013, 12:05:08 PM »
In my experiments with mosfets and high voltages, i need some kind of control over the current that mosfet takes from the battery during switching. I usally put a needle amber-meter in series between load inductor and battery. What i 'd like to confirm is that in this way i measure the mosfet's pulsed current. For example, IRFP460 can handle up tp 80A pulsed current. Is it safe to read an indication of i.e 50A? Is there any other way of measuring this without affecting the current passage?

Tnks
Jeg

TinselKoala

  • Hero Member
  • *****
  • Posts: 13958
Re: Mosfet peak current on duty measurements
« Reply #1 on: November 21, 2013, 09:36:03 PM »
In my experiments with mosfets and high voltages, i need some kind of control over the current that mosfet takes from the battery during switching. I usally put a needle amber-meter in series between load inductor and battery. What i 'd like to confirm is that in this way i measure the mosfet's pulsed current. For example, IRFP460 can handle up tp 80A pulsed current. Is it safe to read an indication of i.e 50A? Is there any other way of measuring this without affecting the current passage?

Tnks
Jeg
Have you measured the series resistance of your needle ampmeter? Mine have DC resistances that are not negligible, even as high as 10 ohms on some scales.
Also, the response time of these meters is slow, so if your pulses are short you may not be getting an accurate indication of peak values but rather may be reading an average value.

The proper way is to use a small current-viewing resistor in series with your mosfet  circuit, and to look at the voltage drop across that resistor with an oscilloscope. If your pulses are long enough you may be able to do this with a DMM instead: put a 0.1 ohm resistor between the mosfet source and the negative supply rail, and use your DMM on the voltmeter scale to look at the voltage across this resistor, then calculate the current based on Ohm's Law. Current in Amperes = Voltage across resistor / resistor value in Ohms.

The mosfet data sheet will give the maximum time of the high current pulse it is rated for. All the mosfet ratings assume that you have it mounted correctly on an appropriate heatsink.

Jeg

  • Hero Member
  • *****
  • Posts: 1532
Re: Mosfet peak current on duty measurements
« Reply #2 on: November 24, 2013, 10:45:48 AM »
Tnks Tins.
I have to say that i couldn't imagine meter's resistance is so high. 418 OHM!!! It was a load itself for my mosfet. I made an other resistance of 10.45 milli Ohms with one meter of AWG15 wire and i saw for a first time how current waveforms look like, by connecting it as you said. I 'll try to find a 0.1 Ohm, because 10.45mOhm is very small and near to the value of solder's paste resistance. This gives me an inaccuracy of many amber.

Jeg

forest

  • Hero Member
  • *****
  • Posts: 4076
Re: Mosfet peak current on duty measurements
« Reply #3 on: November 24, 2013, 07:28:12 PM »
That's my problem too  >:(  It's not easy to predict what reactance (plus resistance) mosfet would see. I can measure inductance quite easily but not resistance of wire if below 10 ohms. I think the best is to have a bit bigger inductance so the resitance is smaller by some factor then reactance for given frequency of switching...


We need a lot more of helpful tips from TinselKoala to avoid damaging precious mosfets. Mine mosfet can switch in impulse some 200A but that is not very big value unfortunately....

forest

  • Hero Member
  • *****
  • Posts: 4076
Re: Mosfet peak current on duty measurements
« Reply #4 on: November 24, 2013, 07:30:45 PM »
For solace be sure Tesla had the same problems.... plenty of his patents are for circuit breaker...