Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1935 on: August 04, 2015, 07:21:34 AM »
hy  Yuri  what s  the  special   ou  can  get   I  have  try  for  months   winding  and  rewind    nanocristal amourfus   core  Hitachi ,with  good  driver    all  frequency   ,  not  really   lot  ou    coming    were  is   the  cat  ?

Sorry, I could not catch Your writting (maybe it is Toki Pona)  :).
Please write English, German, Spainish, Polish, Russian, Ukrainian.
I do not work with nanocristal amourfus core.
It is very expensive in Ukraine and there is no sense to use them at a frequency of 50-60 Hz (this is my point of view)


aaron5120

  • Jr. Member
  • **
  • Posts: 75
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1936 on: August 05, 2015, 04:53:48 AM »
Dear TheCell

There is below  the picture of my first OU-trafo that I was tested a month ago.

As You can see  it is almost as in yours case (maximum power) BUT

You need to reduce turn number of the inductor.....

Hi Yuri_L,
Do you mean placing a shorted loop like the red line I have drawed in the picture of your trafo? If not, please indicate the orientation of the shorted loop placement. Thnx!

Yuri_L

  • Newbie
  • *
  • Posts: 18
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1937 on: August 05, 2015, 07:32:41 AM »
Not quite as you have shown but as on the picture below...

totoalas

  • Hero Member
  • *****
  • Posts: 656
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1938 on: August 05, 2015, 07:35:53 PM »
is the cable loop  just like a battery cable  and what size  thanks

TheCell

  • Sr. Member
  • ****
  • Posts: 285
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1939 on: August 05, 2015, 09:03:32 PM »
@Yuri_L :
I received the clamp meter yesterday.
In the shorted loop I have measured 125A.
<You need to reduce turn number of the inductor...>
For what purpose ? The core will go into saturation.

Yuri_L

  • Newbie
  • *
  • Posts: 18
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1940 on: August 06, 2015, 07:27:04 AM »
I received the clamp meter yesterday.
In the shorted loop I have measured 125A.
<You need to reduce turn number of the inductor...>

You need to reduce turn number of the inductor to get the idle current 250mA
I hope you know how to reduce   the saturation of the core  :D

Cherryman

  • Hero Member
  • *****
  • Posts: 642
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1941 on: August 06, 2015, 10:29:28 AM »
https://www.youtube.com/watch?v=UrxwgaPMXwI


Not sure if this one has gone by.

Yuri_L

  • Newbie
  • *
  • Posts: 18
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1942 on: August 07, 2015, 04:41:45 AM »
is the cable loop  just like a battery cable  and what size  thanks

Size is defined by the temperature that should be not more than 40-50oC

totoalas

  • Hero Member
  • *****
  • Posts: 656
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1943 on: August 07, 2015, 09:11:19 AM »
Size is defined by the temperature that should be not more than 40-50oC

Thanks YUri  for the info
Can a toroid be used also ....  If I use a welding machine( what size for a 2 or 3 KW  output )   for the set up   Can I use the air conditioner as a load  .....  Im thinking to use the toroid  for small heating load such as flat iron  and  rice cooker
lots of possibilities....   ;)
Another question on the loop connection   is it connected in the beginning   1/4  or 1/2  of the coil turns  ???
And coil loop size more than double the primary coil to compensate for the temperature  ????
thanks

tvka

  • Newbie
  • *
  • Posts: 1
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1944 on: August 09, 2015, 01:01:49 PM »
Hi Yuri,

Frankly,your video did not assure me.
Meaning, I do not see  why lamps where not lighted up to full brightness from common 220 net...

However, I prefer  not to spill the water with a child.

I have 200W industrial winding thoroid transformer. Hope it is designed properly regarding primary turn number. Without flux phi2 get 75A in the shorted loop, primary power 22W.

Feels like phi2 does the trick.
Estimated primary turn number is 700.
Please suggest what should be turn number for the counter winded portion of primary.
Is it 1:400 as in your case?
What is the purpose of the shorted loop connection to primary? It will affect fluxes anyway.

Regards,
Valdis


tesletic

  • Newbie
  • *
  • Posts: 46
    • TESLETIC
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1945 on: August 12, 2015, 10:48:31 AM »
Hi all, here sure is a video that will help us understanding more what '' Tesla's ELECTRICITY '' it is REALLY about ! and yes I know yet another claim about OU but personally I think this is for REAL and it is a quantum leap forward for this board!  ;)
Tesla's Secret finally understood (Gerard Morin) https://youtu.be/YZ7I9XgaW3A

slotinnn

  • Newbie
  • *
  • Posts: 18
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1946 on: August 30, 2015, 12:36:03 AM »
hell yuri and thank y for all your strugle with getting free energy.
I m havig 3 questions for y
1.   the looop shortcircuit the secondary and makes secondary witout any current in it so the second flux dissaperas.
2. Here do you get the 3 rd flux because even the loop drives any current in it-even i showed to y it does not- it would have the same direction of the flux like the secondary
3. Where should phi 3 get so much values?

Thank you

To understand how this "magic-loop" creates “Anti-Lenz effect”,  I offer to redraw the "BarboGen"  ones more time with no shorted loop - Fig.6.
As you can see into the core, there are two fluxes Ф1 and Ф2 directed toward each other.

Flux  Ф1 is equal to   Ф1 = u*I1*400 (turns)*S/L

Flux  Ф2 is equal to   Ф2 = u*I1*1 (turn)*S/L
 
where u - magnetic permeability;
S - core section (cm2);
L- the length of the magnetic circuit.

tonygiang

  • Newbie
  • *
  • Posts: 48
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1947 on: August 31, 2015, 03:10:54 AM »
Helo Yuri-L and all !
I have read your intelligent design , an idea : to get approval of patent offices is not difficult , but there are two more important things here is your design work and not its COP how much ?

fer123

  • Newbie
  • *
  • Posts: 48
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1948 on: September 19, 2015, 07:51:27 PM »
Hello somebody knows if we can used standard transformer for the conversion? and finally something about Mr Yuri? Thanks.

Clarence

  • Jr. Member
  • **
  • Posts: 96
Re: Energy from the Ground - Self powered generator by Barbosa and Leal
« Reply #1949 on: October 30, 2015, 04:27:46 PM »
Hello @ ALL,

My latest at Energetic Forum, HA! HA!