Author Topic: Lewin's NCF Experiment and Lecture  (Read 45494 times)

tinman

  • Hero Member
  • *****
  • Posts: 5365
Re: Lewin's NCF Experiment and Lecture
« Reply #60 on: April 28, 2016, 01:03:05 PM »
Ok,so following your instructions Poynt, i ran some lead wires along the resistor loop wire,and away from the solenoid--as seen in pic below.
Happy to report no voltage at all detected across the wire between the resistors after 10 go's. ;)

So i applied the same to the resistors,and also happy to report that i have a total voltage across the resistors that is very close to that of the 980mV measured with the scope probe and ground loop around the solenoid.

So all things are as they should be now ;)
Now-one problem ::). Dose this not confirm Lewins experiment?.


Brad

poynt99

  • TPU-Elite
  • Hero Member
  • *******
  • Posts: 3582
Re: Lewin's NCF Experiment and Lecture
« Reply #61 on: April 28, 2016, 03:25:30 PM »
Ok,so following your instructions Poynt, i ran some lead wires along the resistor loop wire,and away from the solenoid--as seen in pic below.
Happy to report no voltage at all detected across the wire between the resistors after 10 go's. ;)

So i applied the same to the resistors,and also happy to report that i have a total voltage across the resistors that is very close to that of the 980mV measured with the scope probe and ground loop around the solenoid.

So all things are as they should be now ;)
Now-one problem ::) . Dose this not confirm Lewins experiment?.


Brad
Good stuff Brad.

Yes, you have replicated all the results and shown the effects of Lewin's experiment. As such, it would appear that Lewin's emphatic push to denounce Kirchhoff as not holding in such a case seems to be true, correct? (One can easily come to this conclusion because when summing the voltages measured around the loop, we come to the same voltage as the calibrated voltage, and it is not zero as Kirchhoff would prescribe).

Well, Lewin's experiment only demonstrated half the picture, and attempted to mislead the audience into thinking he was measuring potential differences in the circuit. The fact is that this is not entirely true, and the experiment as demonstrated only captures one perspective of reality. He is in fact measuring the E field, and it so happens that the E field in both perspectives overlaps when it comes to the values measured across the resistors. It does not however overlap when it comes to measuring the wire segments.

How then do we examine the experiment from the second perspective (the "real" one Lewin conveniently left out of his demonstration)? Simply make a twin lead cable long enough that it can run from your scope probe, to the ceiling (screw-hook), then drop down right above the solenoid so it can clip onto the various measurement points. This effectively decouples the measurement device from the experiment and permits us to measure the "real" potential differences across all of the components, i.e. the resistors and wire segments in between.

Redo the measurements using this "perspective", and compare your results. Be sure to measure across points D and A again too (i.e. across the middle of the wire segments as per Lewin's diagram), but first try to make a prediction of what voltage (if any) you will measure there.


wattsup

  • Hero Member
  • *****
  • Posts: 2606
    • Spin Conveyance Theory - For a New Perspective...
Re: Lewin's NCF Experiment and Lecture
« Reply #62 on: April 28, 2016, 06:25:48 PM »
Redo the measurements using this "perspective", and compare your results. Be sure to measure across points D and A again too (i.e. across the middle of the wire segments as per Lewin's diagram), but first try to make a prediction of what voltage (if any) you will measure there.

Zero, because the potential will be equal from both sides.

wattsup

poynt99

  • TPU-Elite
  • Hero Member
  • *******
  • Posts: 3582
Re: Lewin's NCF Experiment and Lecture
« Reply #63 on: April 28, 2016, 08:50:29 PM »
Try also to predict what will be measured (if anything) across the wire segments.

Magluvin

  • Hero Member
  • *****
  • Posts: 5884
Re: Lewin's NCF Experiment and Lecture
« Reply #64 on: April 28, 2016, 11:10:09 PM »
Zero, because the potential will be equal from both sides.

wattsup

Should be in normal cases.  But this is sort of a current source event considering the 2 different value resistors are in a current loop and the wires are the current induced parts.

We once did an audio system in a mercedes. We had an engine/alternator wine in the tweeters we just couldnt figure out. Checked all grounds, rca cables. Repl amps, head unit, etc.   Come to find that the passive crossover network box was located near a car wire harness. It was inducing the coils in the crossover. Not that it was the same thing you guys were figuring out, but.....

Nice work on working out the scope lead problems. ;)

Mags


Magluvin

  • Hero Member
  • *****
  • Posts: 5884
Re: Lewin's NCF Experiment and Lecture
« Reply #65 on: April 29, 2016, 12:03:34 AM »
The 2 resistors in a loop with short lengths of wire between the resistors of different value to make the loop is very strange.  Now you could probably do a comparison by switching out the wires for D cells in series circuit.  I might expect the outcome before testing to be total voltage say 3v/1kohm=3ma , then multiply the current and each resistor to come up with the voltage across each resistor. But now Im questioning it a bit. lol

Mags

wattsup

  • Hero Member
  • *****
  • Posts: 2606
    • Spin Conveyance Theory - For a New Perspective...
Re: Lewin's NCF Experiment and Lecture
« Reply #66 on: April 29, 2016, 01:28:36 AM »
Try also to predict what will be measured (if anything) across the wire segments.

Should be the same, Zero since the "impartation" will still be equal all around originating from the vertical coil each portion gets the same share. The resistors should not play into this.

In the previous tests by @tinman, is it possible that the resistors require a certain length of time to actually resist to their rated value and maybe the discharge is faster hence shorter then the actual drop in the resistors?

wattsup

 

Magluvin

  • Hero Member
  • *****
  • Posts: 5884
Re: Lewin's NCF Experiment and Lecture
« Reply #67 on: April 29, 2016, 02:31:15 AM »
Should be the same, Zero since the "impartation" will still be equal all around originating from the vertical coil each portion gets the same share. The resistors should not play into this.

In the previous tests by @tinman, is it possible that the resistors require a certain length of time to actually resist to their rated value and maybe the discharge is faster hence shorter then the actual drop in the resistors?

wattsup

If we think of the 2 wires as current sources, or just very low turn secondaries, then we look at the probe or meter impedance/internal resistance, and the wires current abilities could take that resistance path just like the other resistors take on those currents. So there could be a voltage measurement there I think. Pretty small, but probably not zero.

Mags

wattsup

  • Hero Member
  • *****
  • Posts: 2606
    • Spin Conveyance Theory - For a New Perspective...
Re: Lewin's NCF Experiment and Lecture
« Reply #68 on: April 29, 2016, 03:29:24 AM »
If we think of the 2 wires as current sources, or just very low turn secondaries, then we look at the probe or meter impedance/internal resistance, and the wires current abilities could take that resistance path just like the other resistors take on those currents. So there could be a voltage measurement there I think. Pretty small, but probably not zero.
Mags

@Magsmaman

It's a trick question. The vertical coil is producing a "magnetic" (let's play the game) influence all around. The loop is catching this influence equally all around. The scope probe will see 5 volts and the ground will see 5 volts and the waveform will show the differential being zero volts. The zero volts does not mean there is zero in the loop, only that the scope sees the same energy level at both the probe and the ground clip. Zero does not mean zero. Ouch. We like to "think" that this is producing a "current flow" in "one direction" but that in my view is never the case. Each micron of that loop is its own generator because the vertical coil is only receiving one impulse so only one chance to create some change in the vicinity of the loop so regardless of where you are probing all points are equal so you will always see zero on the scope.

This is what I was trying to explain to @tinman how any times. Measuring across a cvr only means so much and it definitely does not prove "current flow". But again this only depends on how you handle your logic.

wattsup


tinman

  • Hero Member
  • *****
  • Posts: 5365
Re: Lewin's NCF Experiment and Lecture
« Reply #69 on: April 29, 2016, 02:24:01 PM »
Good stuff Brad.

Yes, you have replicated all the results and shown the effects of Lewin's experiment. As such, it would appear that Lewin's emphatic push to denounce Kirchhoff as not holding in such a case seems to be true, correct? (One can easily come to this conclusion because when summing the voltages measured around the loop, we come to the same voltage as the calibrated voltage, and it is not zero as Kirchhoff would prescribe).

Well, Lewin's experiment only demonstrated half the picture, and attempted to mislead the audience into thinking he was measuring potential differences in the circuit. The fact is that this is not entirely true, and the experiment as demonstrated only captures one perspective of reality. He is in fact measuring the E field, and it so happens that the E field in both perspectives overlaps when it comes to the values measured across the resistors. It does not however overlap when it comes to measuring the wire segments.

How then do we examine the experiment from the second perspective (the "real" one Lewin conveniently left out of his demonstration)? Simply make a twin lead cable long enough that it can run from your scope probe, to the ceiling (screw-hook), then drop down right above the solenoid so it can clip onto the various measurement points. This effectively decouples the measurement device from the experiment and permits us to measure the "real" potential differences across all of the components, i.e. the resistors and wire segments in between.

Redo the measurements using this "perspective", and compare your results. Be sure to measure across points D and A again too (i.e. across the middle of the wire segments as per Lewin's diagram), but first try to make a prediction of what voltage (if any) you will measure there.

Ok
Well i would expect that the result's across each resistor would be the same as in the last test,as the two wires leading out from each resistor in the last test, would both see the same electric and magnetic field,and so would cancel out any effect or induced voltage from the E field.
At points A and D (middle of each wire connecting the resistor's) i would expect to see a voltage value that is between(in the middle of) the voltage across the 100R and 1KR resistor-so some where near 400mV.

I have my daughters and grandkids over for a movie/sleep over night,so may not get to testing this tonight--but will see what time they all fall asleep lol.


Brad

ramset

  • Hero Member
  • *****
  • Posts: 8073
Re: Lewin's NCF Experiment and Lecture
« Reply #70 on: April 29, 2016, 03:18:34 PM »
Grandkids and a sleepover !!
Hide the Magnums or it'll be an all nighter !!

[especially those Chocolate Carmel ones ]

 8)

poynt99

  • TPU-Elite
  • Hero Member
  • *******
  • Posts: 3582
Re: Lewin's NCF Experiment and Lecture
« Reply #71 on: April 29, 2016, 04:52:23 PM »
How about the measurement across the wire segments. Any guesses?

wattsup

  • Hero Member
  • *****
  • Posts: 2606
    • Spin Conveyance Theory - For a New Perspective...
Re: Lewin's NCF Experiment and Lecture
« Reply #72 on: April 29, 2016, 06:44:55 PM »
How about the measurement across the wire segments. Any guesses?
Reply 67 & 69

lumen

  • Hero Member
  • *****
  • Posts: 1388
Re: Lewin's NCF Experiment and Lecture
« Reply #73 on: April 30, 2016, 07:41:06 AM »
How about the measurement across the wire segments. Any guesses?

If you can run the probe leads vertical in a manner where current will not be induced in them, then measuring the wire segments will produce about half the signal as when the leads circled the coil. Each segment is a winding on the transformer core and would each provide about half of a full loop current.


Pirate88179

  • elite_member
  • Hero Member
  • ******
  • Posts: 8366
Re: Lewin's NCF Experiment and Lecture
« Reply #74 on: April 30, 2016, 03:23:05 PM »
Would slipping a small Faraday cage (Like a can shaped one) over the coil stop it from influencing the probe wires?  It would seem to me this would be the easiest way if it works.

Bill